[{"data":1,"prerenderedAt":137},["ShallowReactive",2],{"products/skaidulu-nustatymas/lt":3},{"status":4,"data":5},true,{"id":6,"image":7,"seo":11,"title":56,"url":63,"blocks":64},686,{"src":8,"ratio":9,"alt":10,"caption":10},"https://web.labradon.lt/wp-content/uploads/2026/08/slapios-chemijos-analize-opsis-liquidline-fiberroc.jpg",0.55,"",{"title":12,"robots":13,"og_locale":19,"og_type":20,"og_title":12,"og_url":21,"og_site_name":22,"article_modified_time":23,"og_image":24,"twitter_card":30,"schema":31,"language":60},"Skaidulų nustatymas | LabRadon",{"index":14,"follow":15,"max-snippet":16,"max-image-preview":17,"max-video-preview":18},"index","follow","max-snippet:-1","max-image-preview:large","max-video-preview:-1","lt_LT","article","https://www.labradon.lt/produktas/skaidulu-nustatymas/","LabRadon","2026-08-19T12:28:34+00:00",[25],{"width":26,"height":27,"url":28,"type":29},"2560","1439","https://web.labradon.lt/wp-content/uploads/2026/07/image-61-scaled.jpg","image/jpeg","summary_large_image",{"@context":32,"@graph":33},"https://schema.org",[34,46,57],{"@type":35,"@id":21,"url":21,"name":12,"isPartOf":36,"datePublished":38,"dateModified":23,"breadcrumb":39,"inLanguage":41,"potentialAction":42},"WebPage",{"@id":37},"https://www.labradon.lt/#website","2026-08-10T11:52:16+00:00",{"@id":40},"https://www.labradon.lt/produktas/skaidulu-nustatymas/#breadcrumb","lt-LT",[43],{"@type":44,"target":45},"ReadAction",[21],{"@type":47,"@id":40,"itemListElement":48},"BreadcrumbList",[49,54],{"@type":50,"position":51,"name":52,"item":53},"ListItem","1","Home","https://labradon.netlify.app/",{"@type":50,"position":55,"name":56},"2","Skaidulų nustatymas",{"@type":58,"@id":37,"url":59,"name":22,"description":10,"inLanguage":41},"WebSite","https://www.labradon.lt/",[61],{"url":21,"code":62,"locale":62,"default":4},"lt","/produktas/skaidulu-nustatymas/",[65,84,92,97,128,132],{"acf_fc_layout":66,"use_breadcrumbs":4,"title":67,"text":69,"gallery":70,"button":10,"second_button":72,"breadcrumbs":75,"current_page":56},"AcfProductMain",{"text":56,"header":68},"h1","\u003Cp>Skaidulų nustatymas – tai klasikinis šlapiosios chemijos metodas, naudojamas maisto, pašarų, žemės ūkio ir mokslinių tyrimų laboratorijose, kai reikia įvertinti skaidulinių medžiagų kiekį mėginyje. Ši analizė ypač svarbi pašarų kokybės kontrolei, maistinės vertės vertinimui ir žaliavų charakterizavimui.\u003C/p>\n\u003Cp>Skaidulos gali būti nustatomos pagal skirtingus metodus, įskaitant \u003Cstrong>Weende\u003C/strong> metodą žaliajai ląstelienai ir \u003Cstrong>Van Soest\u003C/strong> metodus, skirtus skirtingoms skaidulų frakcijoms, tokioms kaip NDF, ADF ir ADL. Tokie tyrimai padeda geriau įvertinti pašarų virškinamumą, maistinę vertę ir žaliavų kokybę.\u003C/p>\n",[71],{"src":8,"ratio":9,"alt":10,"caption":10},{"title":73,"url":74,"target":10},"SUSISIEKITE SU MUMIS","/kontaktai/",[76,80],{"id":77,"name":78,"url":79},"8","Titulinis","/",{"id":81,"name":82,"url":83},17,"Šlapios chemijos analizė","/kategorija/slapios-chemijos-analize/",{"acf_fc_layout":85,"title":86,"text":87,"button":10,"layout_color":88,"container_size":89,"padding_top":90,"padding_bottom":91},"AcfText",{"text":10,"header":68},"\u003Cp>\u003Cstrong>OPSIS LiquidLINE\u003C/strong> siūlo \u003Cstrong>FiberROC\u003C/strong> skaidulų nustatymo sistemas, skirtas automatizuoti klasikinius Weende ir Van Soest metodus. Šios sistemos padeda sumažinti rankinio darbo kiekį, užtikrinti geresnį rezultatų pakartojamumą ir padidinti laboratorijos našumą.\u003C/p>\n\u003Cp>\u003Cstrong>Pagrindiniai OPSIS FiberROC sistemų privalumai\u003C/strong>\u003C/p>\n\u003Cul>\n\u003Cli>Automatizuotas skaidulų nustatymas pagal Weende ir Van Soest metodus\u003C/li>\n\u003Cli>Tinka žaliosios ląstelienos, NDF, ADF ir ADL nustatymui\u003C/li>\n\u003Cli>Uždara darbo aplinka saugesniam reagentų naudojimui\u003C/li>\n\u003Cli>Automatinis tirpalų pridėjimas ir virinimas slėgyje\u003C/li>\n\u003Cli>Galimybė apdoroti iki 27 mėginių vienoje partijoje\u003C/li>\n\u003Cli>Mažesnis rankinio darbo ir operatoriaus klaidų kiekis\u003C/li>\n\u003Cli>Geresnis rezultatų pakartojamumas\u003C/li>\n\u003Cli>Mažesnės reagentų sąnaudos dirbant su mažesnėmis partijomis\u003C/li>\n\u003Cli>Patogesnis mėginių registravimas, skaičiavimai ir darbo eigos valdymas\u003C/li>\n\u003Cli>Tinka tiek didelio našumo, tiek mažesnėms laboratorijoms\u003C/li>\n\u003C/ul>\n","white","small","pt-default","pb-small",{"acf_fc_layout":85,"title":93,"text":94,"button":10,"layout_color":95,"container_size":89,"padding_top":96,"padding_bottom":91},{"text":10,"header":68},"\u003Cp>\u003Cstrong>Kodėl verta rinktis OPSIS LiquidLINE FiberROC?\u003C/strong>\u003C/p>\n\u003Cp>OPSIS FiberROC sistemos sukurtos laboratorijoms, kurios atlieka skaidulų analizę ir nori modernizuoti klasikinius rankinius metodus. Automatizuotas tirpalų dozavimas, virinimas ir darbo eigos valdymas padeda sumažinti operatoriaus įtaką rezultatams, padidina saugumą ir leidžia vienodomis sąlygomis apdoroti didesnį mėginių kiekį.\u003C/p>\n\u003Cp>FiberROC sprendimai ypač naudingi pašarų ir žemės ūkio laboratorijoms, kur skaidulų analizė atliekama reguliariai, o rezultatų pakartojamumas ir darbo našumas yra labai svarbūs. Priklausomai nuo laboratorijos poreikių, galima rinktis rankinius, automatinius arba pažangesnius FiberROC modelius.\u003C/p>\n","light-blue","pt-small",{"acf_fc_layout":98,"title":99,"text":100,"rows":101,"button":10,"layout_color":88,"container_size":89,"padding_top":96,"padding_bottom":91},"AcfTextGroups",{"text":10,"header":68},"\u003Cp>\u003Cstrong>Pagrindinės taikymo sritys\u003C/strong>\u003C/p>\n\u003Cp>&nbsp;\u003C/p>\n",[102,110,116,122],{"items":103},[104,107],{"column_title":105,"text":106},"Taikymo sritys","\u003Cp>\u003Cstrong>Pašarų laboratorijos\u003C/strong>\u003C/p>\n",{"column_title":108,"text":109},"Tyrimai","\u003Cul>\n\u003Cli>Žaliosios ląstelienos nustatymas\u003C/li>\n\u003Cli>NDF, ADF ir ADL skaidulų frakcijų analizė\u003C/li>\n\u003Cli>Pašarų maistinės vertės vertinimas\u003C/li>\n\u003Cli>Pašarų kokybės kontrolė\u003C/li>\n\u003C/ul>\n",{"items":111},[112,114],{"column_title":105,"text":113},"\u003Cp>\u003Cstrong>Žemės ūkis\u003C/strong>\u003C/p>\n",{"column_title":108,"text":115},"\u003Cul>\n\u003Cli>Grūdų, sėklų ir augalinių žaliavų analizė\u003C/li>\n\u003Cli>Augalinės kilmės mėginių skaidulų tyrimai\u003C/li>\n\u003Cli>Žaliavų tinkamumo vertinimas\u003C/li>\n\u003C/ul>\n",{"items":117},[118,120],{"column_title":105,"text":119},"\u003Cp>\u003Cstrong>Maisto pramonė\u003C/strong>\u003C/p>\n",{"column_title":108,"text":121},"\u003Cul>\n\u003Cli>Skaidulų kiekio nustatymas maisto produktuose\u003C/li>\n\u003Cli>Produktų sudėties ir kokybės kontrolė\u003C/li>\n\u003Cli>Maistinės vertės vertinimas\u003C/li>\n\u003C/ul>\n",{"items":123},[124,126],{"column_title":105,"text":125},"\u003Cp>\u003Cstrong>Moksliniai tyrimai\u003C/strong>\u003C/p>\n",{"column_title":108,"text":127},"\u003Cul>\n\u003Cli>Pašarų ir augalinių žaliavų charakterizavimas\u003C/li>\n\u003Cli>Virškinamumo ir maistinės vertės tyrimai\u003C/li>\n\u003Cli>Metodų kūrimas ir palyginimas\u003C/li>\n\u003C/ul>\n",{"acf_fc_layout":85,"title":129,"text":130,"button":10,"layout_color":88,"container_size":89,"padding_top":90,"padding_bottom":131},{"text":10,"header":68},"\u003Cp>\u003Cstrong>OPSIS FiberROC sprendimai jūsų laboratorijai\u003C/strong>\u003C/p>\n\u003Cp>OPSIS LiquidLINE FiberROC sistemos leidžia efektyviai atlikti skaidulų nustatymą pagal klasikinius Weende ir Van Soest metodus. Mažesnėms laboratorijoms gali būti tinkami paprastesni arba rankiniai sprendimai, o didelio mėginių srauto laboratorijoms – FiberROC Auto arba FiberROC Advanced sistemos.\u003C/p>\n\u003Cp>&nbsp;\u003C/p>\n\u003Cp style=\"text-align: center;\">\u003Cstrong>Sužinokite daugiau\u003C/strong>\u003C/p>\n\u003Cp>&nbsp;\u003C/p>\n","pb-none",{"acf_fc_layout":133,"title":134,"layout_color":88,"container_size":89,"padding_top":135,"padding_bottom":136},"AcfContactForm",{"text":10,"header":68},"pt-none","pb-default",1787317468633]